OPERATOR’S MANUAL
ISO
6
Version 4 UL 2_3 Manual
COMPONENT INSTALLATION / 19
6011258 Rev C
SYSTEM MODES
INTELLIAG ISO
6
ACCESS
The IntelliAg system is accessed by pressing the ISO
6
button
located i
n the UT’s working set list.
The ISO
6
Control System has two modes of operation:
Work Mode (master/control switch ON or implement
DOWN).
System Setup (Level 2 and 3 users are accessible
with password).
WORK MODE
When the master/control switch is in the ON position, the
START
button is pressed with the implement down, ground speed is
greater than 0, or the minimum ground speed is shutoff; the
ISO
6
Control System is in Work Mode. In this mode, all enabled
system components and control channels are operational, as
well as all monitoring functions and system accumulators.
When the master switch is in the OFF position or the
STOP
button is pressed (red), the implement up, or ground speed is 0
or less than the defined ground speed shutoff, all control and row
monitoring functions cease.
Figure 15
IntelliAg ISO
6
Icon and Work Mode Active