OPERATOR’S MANUAL
ISO
6
Version 4 UL 2_3 Manual
GRANULAR SEEDING MATERIAL TYPE / 53
6011258 Rev C
IMPORTANT
The maximum or minimum rates may not be reached
if the % increase or decrease, based off the Target Rate,
exceeds the maximum or minimum rate limits set.
EXAMPLE:
Maximum Rate is set for 101. Target Rate is set for
100. If the % increase is set at 2%, the maximum rate of 101 will
not be met because the % increase of 2% would exceed the 101
maximum rate limit.
DENSITY
Density is the weight per volume of material to be dispensed and
is required to convert the spreader constant. May be in units of
LB/FT3, LB/BU, or KG/L.
PRECHARGE
See “Using the PreCharge Feature” for more information on
PreCharge setup.
DISTANCE DELAY
The delay in M or FT that the implement must travel before the
Channel is turned on or off. Distance Delay does not function if
the Task Controller is connected and active.
SEEDS PER POUND
The number (#) of seeds per pound (S/LB) or seeds per kilogram
(S/KG). This setting is used when calculating population values
and triggering alarms. The Seeds per Pound is also used when
material Units are set to KS/AC or Seeds/Ft2 to convert the
target rate to LBS/AC or KG/HA. Editing this setting will update
the Thousand Grain Weight setting.
This number is often found printed on the seed bag. This setting
is only used for materials with Seeding type for Product Class.