LIQUID FLOW MATERIAL TYPE / 57
6011258 Rev C
PRESET METHOD DISABLED
When Preset Method is disabled, the target rate on the
Work Screen can be adjusted by pressing the Material
Increment/Decrement buttons. The target rate increases or
decreases based on the Inc/Dec % value set at the Material
Configuration screen.
TARGET RATE
Target Rate establishes the desired rate of application in gallons
per acre (GAL/AC) or liters per hectare (L/HA).
MAXIMUM RATE
Establishes the maximum application rate in gallons per acre
(GAL/AC) or liters per hectare (L/HA) that the control will allow.
Target Rate cannot be incremented to a value greater than this
established maximum rate.
MINIMUM RATE
Establishes the minimum application rate in gallons per acre
(GAL/AC) or liters per hectare (L/HA) that the control will allow.
Target Rate cannot be decremented to a value lower than this
established minimum rate.
INCREASE/DECREASE %
The Increment/Decrement Percent rate establishes the
percentage of change that is applied each time the
Increment/Decrement button is pressed on the Work Screen.
IMPORTANT
The maximum or minimum rates may not be reached if the
% increase or decrease, based off the Target Rate,
exceeds the maximum or minimum rate limits set.
EXAMPLE:
Maximum Rate is set for 101. Target Rate is set for
100. If the % increase is set at 2%, the maximum rate of 101 will
not be met because the % increase of 2% would exceed the 101
maximum rate limit.