OPERATOR’S MANUAL
60 / PLANTER MONITOR MATERIAL TYPE
ISO
6
Version 4 UL 2_3 Manual
6011258 Rev C
MAXIMUM RATE
Maximum Rate establishes the maximum application rate in
thousands of seed per acre (KS/AC) or thousands of seeds
per hectare (KS/HA) that the control allows. Target Rate
cannot be incremented to a value greater than this established
maximum rate.
MINIMUM RATE
Minimum Rate establishes the minimum application rate in
thousands of seed per acre (KS/AC) or thousands of seeds
per hectare (KS/HA) that the control allows. Target Rate
cannot be decremented to a value lower than this established
minimum rate.
INCREASE/DECREASE %
The Increment/Decrement Percent rate establishes the
percentage of change that is applied each time the
Increment/Decrement button is pressed on the Work Screen.
IMPORTANT
The maximum or minimum rates may not be reached if the
% increase or decrease, based off the Target Rate,
exceeds the maximum or minimum rate limits set.
EXAMPLE:
Maximum Rate is set for 101. Target Rate is set for
100. If the % increase is set at 2%, the maximum rate of 101 will
not be met because the % increase of 2% would exceed the 101
maximum rate limit.
SEEDS PER REV
Displays the number of seeds that are dropped in one revolution
of the seed disk.
NOTE
Press the Arrow button on the Materials screen to view
second screen.