OPERATOR’S MANUAL
64 / GRANULAR MONITOR MATERIAL TYPE
ISO
6
Version 4 UL 2_3 Manual
6011258 Rev C
TARGET RATE
Target Rate establishes the desired rate of application in pounds
per acre.
MAXIMUM RATE
Maximum Rate establishes the maximum application rate in
pounds per acre (LB/AC) or kilograms per hectare (KG/HA) that
the control will allow. Target Rate cannot be incremented to a
value greater than this established maximum rate.
MINIMUM RATE
Minimum Rate establishes the minimum application rate in
pounds per acre (LB/AC) or kilograms per hectare (KG/HA) that
the control will allow. Target Rate cannot be decremented to a
value lower than this established minimum rate.
INCREASE/DECREASE %
The Increment/Decrement Percent rate establishes the
percentage of change that will be applied each time the
Increment/Decrement button is pressed on the Work Screen.
IMPORTANT
The maximum or minimum rates may not be reached if the
% increase or decrease, based off the Target Rate,
exceeds the maximum or minimum rate limits set.
EXAMPLE:
Maximum Rate is set for 101. Target Rate is set for
100. If the % increase is set at 2%, the maximum rate of 101 will
not be met because the % increase of 2% would exceed the 101
maximum rate limit.
DENSITY
Density is the weight per volume of material to be dispensed and
is required to convert the spreader constant. May be in units of
LB/FT3, LB/BU, or KG/L.
SEEDS PER POUND
The number (#) of seeds per pound (S/LB) or seeds per kilogram
(S/KG). This setting is used when calculating population values
and triggering alarms. The Seed Per Pound is also used when
material Units are set to KS/AC or Seeds/Ft2 to convert the
target rate to LBS/AC or KG/HA. Editing this setting will update
the Thousand Grain Weight setting. This number is often found
printed on the seed bag.