OPERATOR’S MANUAL
ISO
6
Version 4 UL 2_3 Manual
GRANULAR MONITOR MATERIAL TYPE / 65
6011258 Rev C
This setting is only used for materials with Seeding type for
Product Class.
Figure 44
Material Setup-Granular Monitor Page 2
THOUSAND WEIGHT GRAIN
The weight of 1000 seeds in either ounces or grams. This setting
is used when calculating population values and triggering
alarms. The Thousand Grain Weight is also used when material
Units are set to KS/AC or Seeds/Ft2 to convert the target rate to
LBS/AC or KG/HA. Editing this setting will update the Seeds Per
Pound setting.
This number can be found by counting out 1000 seeds and
weighing them, or it may be printed on the seed bag.
This setting is only used for materials with Seeding type for
Product Class.
HIGH/LOW POPULATION ALARMS
Set when an alarm and row indicator displays to warn of a
population problem. The values are % based. The high and low
population values are independent of each other and do not
have to be the same percentage value. This setting is only used
for materials with Seeding type for Product Class.
ROW FAIL RATE
Sets the threshold for row failure alarms. The value is entered in
seeds per second. Both values are adjustable allowing for
numerous combinations. The default value is 2/1 which indicates