OPERATOR’S MANUAL
ISO
6
Version 4 UL 2_3 Manual
SHAFT CONTROL / 67
6011258 Rev C
PRESET METHOD ENABLED
The Preset Method table allows 10 user-defined target rates to
be entered. When enabled, target rates can be adjusted from the
Work Screen using the Increment/Decrement buttons.
PRESET METHOD DISABLED
When Preset Method is disabled, the target rate on the
Work Screen can be adjusted by pressing the Material
Increment/Decrement buttons. The target rate increases or
decreases based on the Inc/Dec % value set at the Material
Configuration screen.
TARGET RATE
Target Rate establishes the desired rate of application according
to the units specified in the Units setting.
MAXIMUM/MINIMUM RATE
Maximum Rate establishes the maximum application rate in
RPM. Target Rate cannot be incremented to a value greater than
this established maximum rate.
Minimum Rate establishes the minimum application rate in RPM.
Target Rate cannot be decremented to a value lower than this
established minimum rate.
INCREASE/DECREASE %
The Increment/Decrement percent rate establishes the
percentage of change of the entered target rate to be applied
each time the Increment/ Decrement button is pressed on the
Work Screen.
The maximum or minimum rates may not be reached if the %
increase or decrease, based off the target rate, exceeds the
maximum or minimum rate limits set.
NOTE
Press the Arrow button on the Materials screen to view
second screen.