OPERATOR’S MANUAL
ISO
6
Version 4 UL 2_3 Manual
PLANTER CONTROL CHANNEL / 75
6011258 Rev C
PLANTER CONTROL CHANNEL
A Planter Control channel contains the parameters to control the
application rate of a row crop planter.
Figure 53
Planter Control Setup
MATERIAL NAME
Display the material name assigned to the channel. This value
can be changed by editing Configurations in the Material screen.
CONTROL MODE
Auto-Control Channel is calculating application rates
based on ground speed and row spacing under normal
operating conditions.
MANUAL WITH FEEDBACK -
Overrides the current system
when not operating properly, e.g. Faulty coil. Using the
increment/decrement buttons at the main operate screen will set
the rate for the control channel. Manual mode with feedback
shows the actual application rate applied based on actual ground
speed and constants.
MANUAL WITHOUT FEEDBACK -
Overrides the current
system when not operating properly, e.g. Bad feedback sensor.
Using the increment/ decrement buttons at the work screen will
set the rate for the control channel. No application rate feedback
will display.