OPERATOR’S MANUAL
88 / FAN CONTROL
ISO
6
Version 4 UL 2_3 Manual
6011258 Rev C
FAN CONTROL
The following constants define the parameters for fan control.
Figure 60
Fan Control Channel Setup
MATERIAL NAME
Display the material assigned to the channel. This value can be
changed by editing the configurations in the Material screen.
CONTROL MODE
Auto-Control Channel is calculating application rates based on
ground speed and row spacing under normal operating
conditions.
MANUAL WITH FEEDBACK -
Overrides the current system
when not operating properly, e.g. faulty coil. Using the
Increment/Decrement buttons at the Main Operate screen will
set the rate for the control channel. Manual Mode with Feedback
shows the actual application rate applied based on actual ground
speed and constants.
MANUAL WITHOUT FEEDBACK -
Overrides the current
system when not operating properly, e.g. bad feedback sensor.
Using the Increment/ Decrement buttons at the Work Screen will
set the rate for the control channel. No application rate feedback
will display.