90 / FAN CONTROL
ISO
6
Version 4 UL 2_3 Manual
6011258 Rev C
DISABLE CONTROL ON CONTROL
FAILURE ALARM
Select “Enabled” to turn off ALL non-fan control channels when
the RPM value of the sensor falls below the low alarm level
setting.
The two settings include:
ENABLED
- control channels shut down when the RPM
value falls below the low warning setting.
DISABLED
- will disable the function. Control channels
continue to operate normally regardless of the RPM value.
However, when the low RPM state occurs, the information
alarm still occurs.
SHAFT CONTROL
The following constants define the parameters for Shaft Control.
Figure 61
Shaft Control Channel Setup
MATERIAL NAME
Display the material assigned to the channel. This value can be
changed by editing the configurations in the Material screen.