OPERATOR’S MANUAL
ISO
6
Version 4 UL 2_3 Manual
DROP SPREADER / 93
6011258 Rev C
DROP SPREADER
The following constants define the parameters for
Drop Spreader.
Figure 63
Drop Spreader Channel Setup
MATERIAL NAME
Display the material assigned to the channel.
SPINNER OUTPUT PWM (PULSE WIDTH
MODULATION)
A valve, usually hydraulic, which varies the oil flow to a hydraulic
motor proportioned to electric current supplied. This type of valve
consists of a flow cartridge and coil assembly.
GATE OUTPUT
SERVO
A ball valve or butterfly valve that is driven by an electric motor
gearbox and the valve is installed in the tank return line.
DRIVE FREQUENCY
Specifies the drive frequency for the PWM channel on the
Spinner Output. The recommended setting for this option should
be specified from the valve manufacturer.