PERFORM A LIQUID FLOW CATCH TEST
CAUTION
Tanks must contain material. Be prepared to catch the
material in a container so it can be weighed at the end of
the calibration.
DANGER
When the START key is engaged, the machine will
become operational. All necessary precautions must be
taken to ensure user safety. Failure to practice all
necessary caution may result in serious injury or death.
1. At the Liquid Control setup screen, press the
K-FACTOR CAL
button.
2. Enter the Target Ground Speed and Target Flow Rate to
calculate the operation rate.
3. Press the
START
button.
4. Press
STOP
button when container is full.
5. Enter amount (gallons) dispensed in the Total Amount
Collect field.
6. Press
SAVE
button to accept the selection.
7. The system automatically calculates and saves the new
K-Factor for this material.
Figure 68
K-Factor Screen