OPERATOR’S MANUAL
104 / SECTION CONTROL
ISO
6
Version 4 UL 2_3 Manual
6011258 Rev C
SECTION CONTROL
CLUTCH SECTIONS
ROW CROP PLANTER
Auto Section Control is an automated row shutoff system that
automatically shuts off individual sections utilizing a GPS signal
as previously planted areas are approached. Manual control is
also possible using optional equipment.
Required:
ISO
6
Master Module
Output Module(s)
Harnessing
Clutch/Hardware system
Optional:
Switch Module(s)
Virtual Switch feature key
IDENTIFY SECTIONS AND OUTPUTS
MULTIPLE OUTPUT MODULE ASSIGNMENT
Output module addresses are a critical parameter used to
identify a module’s position on the implement that controls row
shutoff switches. There is a 24 clutch maximum.
IMPORTANT
If a planter uses more than one output module, modules
MUST be installed in increasing serial number order
starting on the left side and proceeding to the right so
that row assignment is configured correctly.
TO ENTER # OF OUTPUTS PER MODULE:
1. Press the
CLUTCH SECTIONS
button.
2. At the Clutch Sections screen, enter the total number of
sections.
3. Enter the number of solenoid outputs for each module.
Outputs do NOT always total the number of clutches but the
total number of controlled solenoids. The Outputs column
value is automatically sequenced for each module based on
the module address value.
4. Press the Arrow button to assign channels, rows, outputs,
and switches.