OPERATOR’S MANUAL
ISO
6
Version 4 UL 2_3 Manual
ACCESSORY SENSORS / 133
6011258 Rev C
ACCESSORY ALARM SETUP
Page 2 of the accessory setup contains common alarm settings.
Each accessory type shares these alarm parameters:
SENSOR NAME
Pressing the Sensor Name field at the top right can change the
desired name for the sensor.
HIGH/LOW ALARM LEVEL
Enter a value for the sensor type at which the high/low warning
alarm alerts an out-of-limits state.
HIGH/LOW ALARM DELAY
Enter a value in seconds that creates a delay between the
detection of a high/low alarm condition and the resulting
alarm display.
HIGH/LOW ALARM GATING
Select where high/low alarms should display:
None:
Accessory alarms can appear regardless of the
system state.
In Work:
Accessory alarms can only appear in the
Work Screen.
Safety Input Active:
Accessory alarms can only appear the
Safety Input is active.
Implement Down In Work:
Accessory alarms can only
appear when in the Work Screen with the implement down.
HIGH/LOW ALARM BEHAVIOR
Select how often high/low alarms should display:
No Alarms:
Accessory alarms cannot display.
Repeatedly:
Accessory alarms can display continuously.
Pressing
CANCEL
when the alarm comes up will temporarily
disable the alarm until the alarm state is reentered.
Once Per Power Cycle:
Accessory alarms can display only
once per power cycle.
Once Per Safety Input:
Accessory alarms can display only
once per Safety Input cycle.
Once Per Imp Lift:
Accessory alarms can display only once
per implement lift cycle.