3. Securely tighten tie-strap.
4. Install a second tie-strap toward the label end of the
enclosure for additional support.
Figure 8
Working Set Member Installation (Tie-Strap)
5. Connect a WSMB harness to the WSMB module and
connect the WSMB harness to the Power/CAN backbone,
refer to (Figure 11).
6. Connect each module harness to its module inserting both
connectors until the connector locking tabs engage.
7. Layout the planter harness along the implement frame to
each of the seed sensors.
-
For seed sensors, extensions will most likely not be
necessary.
8. Route sensor wires in locations where they will not be
damaged by chains, drive shafts, sprockets, etc.
9.
Secure the harness to the toolbar with a minimum of 3”
straight wire exiting the module before bending and
attaching with tie-straps.
10. Coil and secure any unused sensor connections.
11. The WSMB Module harness can accept a standard
DICKEY-john PM style planter harness (single round 37-pin
connector) or an SE style planter harness (1 gray 12-pin,
1 black 12-pin rectangular connector) depending on the
WSMB harness. Harnesses are available for a number of
row configurations.
-
Route the planter harness on the implement, securing
as necessary.
-
Install seed sensors per the instructions included with
the sensors. Refer to the implement harness diagram for