OPERATOR’S MANUAL
136 / ACCESSORY SENSORS
ISO
6
Version 4 UL 2_3 Manual
6011258 Rev C
LOGIC LEVEL
Sets the active state of the sensor and allows flexibility to
connect sensors that have different active outputs. There are two
settings available:
ACTIVE HI
-
Sets the active state to “High” signifying that an
alarm is generated if the sensor’s output is in a high state.
Use this setting if the connected sensor outputs a high
condition when active.
ACTIVE LO
-
Sets the active state to “Low” signifying that an
alarm is generated if the sensor’s output is in a low state.
Use this setting if the connected sensor outputs a low
condition when active.
LOGIC LEVEL TABLE
ENSOR LOGIC LEVEL
VALUE
HOPPER
STATUS
ALARM
Active High
0
Full
Blocked
No alarm
Active High
1
Empty
Not Blocked
Alarm
Active Low
0
Empty
Not Blocked
Alarm
Active Low
1
Full
Blocked
No Alarm
Refer to Accessory Alarm Setup for details on alarm setup for
Hopper Sensors.
RPM SENSOR SETUP
IMPORTANT
Performing an Auto Config does not detect installed
RPM sensors.
Figure 99
RPM Setup Screen
SENSOR NAME
Pressing the Sensor Name field at the top right can change the
desired name for the sensor.