OPERATOR’S MANUAL
186 / SYSTEM TEST
ISO
6
Version 4 UL 2_3 Manual
6011258 Rev C
Figure 146
5 Rev Test Screen
TEST GROUND SPEED
The ground speed reference used to perform the test.
ROW
The active row configured in the system. The row that is set here
is the row that reports a seed count in the Test Seed Count
value. The operator can change the row # to get the seed count
of all rows during the test.
TEST TARGET POPULATION
The seed rate at which the test is performed. This value is the
current target rate and is automatically populated.
TEST SEED COUNT
The seed count that automatically populates on a specified
row set.
REMOTE TEST SWITCH
A momentary switch can be purchased from DICKEY-john that
allows the control to be turned on when pressed and held during
the fill disk, valve calibration, K-Factor calibration, spreader
calibration, continuous test, and 5 Rev tests. Releasing the
button stops the operations. Using a remote test switch allows
the operator to go back to the implement to perform the test and
investigate mechanical issues or perform seed counts instead of
performing the test inside the cab from the terminal. The test
switch only functions when the implement switch is in the up
(off) position.