OPERATOR’S MANUAL
ISO
6
Version 4 UL 2_3 Manual
CONTROL CHANNEL SETUP / 73
6011258 Rev C
COPY A CONTROL CHANNEL
A control channel’s setup parameters can be copied to
another channel.
1. Select to highlight the control channel to copy.
2. Press the
COPY
button.
-
The copied channel appears in the next open
channel space.
Figure 51
Clear a Channel
CHANNEL LINKING
Material application control channels can be linked together in a
master/ subordinate relationship. This allows for simultaneous
on/off and rate control from the Work Screen.
TO LINK CHANNELS:
1. At the Control screen, press the
CHANNEL LINKING
button.
2. At the Channel Linking screen, press the
ADD LINK
button.
3. Select the link type as:
-
Rate:
linking the rates of multiple channels.
-
On/Off:
Linking channels to simultaneously turn
ON and OFF.
-
Master/Subordinate:
Links a master/subordinate output
to simultaneously turn on/off channels, i.e. planter
control channel/fan.
-
Accessory:
Allows an accessory alarm to turn the linked
channel(s) off.
4. Press the channels input box to select the channels to link.
-
Continue to press the
ADD LINK
button until are links
are complete.
5. When finished, press the Back button.
6. The new link type and channels display on the Channel
Linking screen.
7. To edit a link, select a specific link and press the
EDIT