Page 5
MAINTENANCE INSTRUCTIONS
Refer to Fig. 4 to access lower chamber of unit where vacuum is located.
Remove and clean the vacuum filter and canister once a week. Dump
dirt from the canister. Tap loose debris from air filter or use an air hose to
clean out the air filter.
Replace air filter (TSI PN 12243-1) every 3 months depending on use.
Refer to vacuum maintenance instructions included with the WC-15 unit
for more detailed cleaning directions.
Facing unit an access panel is
located to the right. Turn power
OFF before opening door.
Remove the six 1/4-20 screws to
open door.
Lift vacuum out from inside the
unit. Unlatch canister from motor
housing and dispose contents.
Inspect air filter and clean as
necessary.
Replace parts in reverse order.
Fig. 4
Fig. 5
To service the chain
and other items
located below the
main unit, remove
the screws on each
end of the unit. The
red arrows in Fig. 5
show their location
on one side.
This same access is
used to add grease
to the four roller
driven bearings.