Number
Index
Name
Unit
Setting range
Default
value
Effective
time
5
0x2005
software
position limit
Maximum
pos
unit
-2147483648~
2147483647
2147483647 Immediately
Parameter Description:
User permission:
User/Engineer.
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
128
0x6080
Maximum motor
speed
r/min
1~10000
3000
Immediately
Parameter description:
Set the maximum allowable motor speed, which should not exceed the highest speed
given by the motor manufacturer. This parameter is set for motor protection, and thus the target speed should be
limited by the set value.