Tsino-Dynatron Electrical Technology (Beijing) Co., Ltd.
Parameter description:
When the overload multiple of the servo motor reaches this set value, and the lasting
time exceeds the overload protection time set in 0x202E, the servo drive will report motor U/V/W instantaneous
overload protection.
User permission:
User/Engineer.
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
150
0x202E
Motor Fast
Overload Alarm
Time
s
1~60
10
Immediately
Parameter description:
This parameter should be used together with 0x202D. For details, please refer to
description of 0x202D.
User permission:
User/Engineer.
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
159
0x20C9
Motor thermal
time constant
sec
60~3600
1100
Restart
Parameter description:
It is used for motor continuous overload protection.
Parameter permission:
Read only
Figure 7.7-3.
Motor overload protection curve
Communication Setting
7.7.5
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
108
0x6007
Abort·connection
·option·code
-
0x0000~0x0003
0x0000
Immediately
130
Summary of Contents for EtherCAT CoolDrive RC Series
Page 1: ...Updated on Update summary Updated version Version number D3 ...
Page 17: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC3 2 3 2 7 ...
Page 18: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC4 2 3 3 8 ...
Page 19: ...Tsino Dynatron Electrical Technology Beijing Co Ltd 9 ...
Page 20: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC6 2 3 4 1 ...