Tsino-Dynatron Electrical Technology (Beijing) Co., Ltd.
User permission:
User/Engineer
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
63
0x2061
command notch
filter 1 center
frequency
Hz
10~60000
6000
Immediately
User permission:
User/Engineer
Parameter permission:
Read and Write
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
64
0x2062
command notch
filter 1
bandwidth
0.1Hz
10~600
10
Immediately
User permission:
User/Engineer
Parameter permission:
Read and Write
Others
7.11
Inverter Rated Current
7.11.1
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
146
0x2086
Inverter Rated
Current
mA
0~2147483647
100
Read only
Parameter description:
The drive's rated output current, which is consistent with the rated current of the
drive with the corresponding model, and is read only.
User permission:
User/Engineer/Designer.
Parameter permission:
Read and Write
Encoder Resetting
7.11.2
R4/R6 drives adopt two ways to reset an encoder, which are:
1. Multi-turn values of an encoder can be reset through the encoder resetting function of the DriveStarter
upper debugging software (at this time, the servo is controlled by DriveStarter). Detailed procedures: Open upper
debuggi
ng software of DriveStarter→connect→switch the control to DriveStarter→function→encoder resetting.
179
Summary of Contents for EtherCAT CoolDrive RC Series
Page 1: ...Updated on Update summary Updated version Version number D3 ...
Page 17: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC3 2 3 2 7 ...
Page 18: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC4 2 3 3 8 ...
Page 19: ...Tsino Dynatron Electrical Technology Beijing Co Ltd 9 ...
Page 20: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC6 2 3 4 1 ...