Parameter description:
When the set motor speed of 0x20CA starts, and before reaching the DC Bus speed
limit, the flux weaking compensation current gradually increases according to the set slope of 0x20CB, until the
current amplitude or motor speed reach the profile command value.
DC bus voltage speed limit
Weak magnetism
compensation
deviation point speed
Excitation current
Motor
speed
t
‰
0
0x20CB=0
DC bus voltage speed limit
Weak magnetism
compensation deviation
point speed
Excitation current
Motor
speed
t
‰
0
0x20CB=100
Max weak magnetic current
Max weak magnetic current
User permission:
User/Professional.
Parameter permission:
Read and Write
Rotor Compensation Angle Detection
7.11.7
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
95
0x20D1
Rotor Compensation
Angle Detection Setting
—
0x00000000~0x1F1F0F01 0x0A190100
Restart
Byte0: Detection method selection
0x01 - Conventional detection method
0x02 - Static detection method
Byte1: Phase sequence detection sensitivity of static detection method
0x01 - 0.1 ºC
0x02 - 0.2 ºC
0x03 - 0.3 ºC
0x04 - 0.4 ºC
0x05 - 0.5 ºC
0x06 - 0.05 ºC
0x07 - 0.02 ºC
0x08 - 0.01 ºC
0x09 - 0.005 ºC
0x0A - 0.001 ºC
182
Summary of Contents for EtherCAT CoolDrive RC Series
Page 1: ...Updated on Update summary Updated version Version number D3 ...
Page 17: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC3 2 3 2 7 ...
Page 18: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC4 2 3 3 8 ...
Page 19: ...Tsino Dynatron Electrical Technology Beijing Co Ltd 9 ...
Page 20: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC6 2 3 4 1 ...