15
Incorrects functions is signalled by leds (rep 26) display flashing correspond with chart below.
Notes
13
Incorrect function
CODE
FAULT
INFORMATION
30 40 50 60 70 80
Overheating safety feature
Overheating defect without locking
Misfiring safety feature
Fire detection without burner working
Besides freezing pump
Besides freezing burnerr
Lack of water circulation.
Primary water circulation defect
Thermistor sanitary open
Thermistor sanitary bypassed.
Thermistor inlet heating open
Thermistor inlet heating bypassed
Extractor on and pressure regulator at rest
Extractor off and pressure regulator at rest
Thermistor cylinder open
Thermistor cylinder bypassed
Distribution valve stuck on heating
=
LED off
=
LED blinking
Summary of Contents for Calydra Comfort 100 Nat
Page 48: ...110...