10
Incorrects functions is signalled by leds (rep 26) display flashing correspond with chart below.
INCORRECT FUNCTION
CODE
FAULT
INFORMATION
30 40 50 60 70 80
m m m m m l
Overheating safety feature
m m m m l m
Overheating defect without locking
m m m m l l
Misfiring safety feature
m m m l m m
Fire detection without burner working
m m m l m l
Besides freezing pump
m m m l l m
Besides freezing burnerr
m m m l l l
Lack of water circulation.
m m l m m m
Primary water circulation defect
m m l m m l
Thermistor sanitary open
m m l m l m
Thermistor sanitary bypassed.
m m l m l l
Thermistor inlet heating open
m m l l m m
Thermistor inlet heating bypassed
m l m l m l
Extractor on and pressure regulator at rest
m l m l l m
Extractor off and pressure regulator at rest
m l l m m l
Thermistor cylinder open
m l l m l m
Thermistor cylinder bypassed
m l l l m l
Distribution valve stuck on heating
m
=
LED off
l
=
LED blinking
Summary of Contents for Calydra Comfort 100 Nat