30
20
11
12
13
14
10
9
8
7
6
5
4
3
2
1
18
19
16
21
17
15
Gap
Manual release holes
1) 0.1kW brake is not provided with fan.
2) 400V motor has 4 motor lead wires.
■
Brake Structure and Gap Adjustment
(1) SLB brake structure
【
Three phase 0.1 – 2.2kW
】
(2)
Manual release
1 Counter-load bracket with yoke
12 Angular hub
2 Coil
13 Retaining ring
3 Armature
14 Key
4 Spring
15 Spring pin
5 Collar
16 Brake spring
6 Brake plate
17 Screw for fixing the fan cover
7 U-nut
18 DC Module
8 Guide bolt
19 Closed-end splice
9 Lining
20 Hole for manual releasing
10 Fan cover
21 Leaf spring
11 Fan
Remove the fan cover
20
. Insert an M5 screws or M5
hexagon head cap bolts (Effective length 10 - 15 mm),
into the manual release holes
20
and screw them in.
When the screws or bolts begin to tighten, screw a
further 1/3 to 1/2 rotation. The brake gap is now
roughly zero and the brake is released. A fan
11
of
range 0.2kw to 0.75kW has been installed.
If one of the holes
20
is hidden by the fan, insert
the M5 screw and slightly release the brake.
Then gently move the fan by hand and insert the other
screw. After completing the work, remove the M5
screws from the brake body. Re-fix the fan cover and
start operation.
If operation is begun while the brake is released accidents may occur.
(3) Gap
adjustment
When the gap reaches its limit value, the brake cannot be released. When the gap approaches its limit,
inspect and adjust. Depending on the operating conditions, the gap limit value may be reached earlier.
Hex socket bolt permissible
M5 screw (length 10mm-15mm)
Brake
plate hole
B
rak
e gap