TSUBAKI E&M CO.
- 4 -
Lubrication and Maintenance* for MZEU90 to MZEU150
1. Apply a suitable amount of oil before use.
2. As a general rule, the amount of lubricant should be level with the center of the shaft for overrunning or backstopping application.
3. The E2 flange has three plugs.
The E4 cover has a large plug for adding oil and two small plugs for checking and draining.
4. Place the plugs, so that one is at the top and one is at the bottom. The center one should be level with the center of the shaft
5. Pour oil into the clutch until it over flows from check plug. After a few minutes, pour in more oil and check that it overflow again.