MODEL
442A
TSURUGA ELECTRIC CORPORATION
9
5.2 Operation function setting
5.2.1 Interface, Printing direction setting
Use DIP switch at bottom.
Switch while power off.
6
Upright printing/Inverted printing
OFF
Upright printing (at delivery)
ON Inverted
printing
4 5 Parity
RS-232C/USB
OFF
OFF
None (at delivery)
ON OFF
Even
OFF
ON Odd
ON ON None
2 3 Transmission
speed
RS-232C/USB
OFF
OFF
4800 bps (at delivery)
ON OFF
9600
bps
OFF
ON 19200
bps
ON ON 38400
bps
1
Input interface
- Invalid at E2
OFF
Conform to centronics (at delivery)
ON RS-232C
●
Parallel (Conform to centronics) setting
At delivery
●
Serial (RS-232C) setting
DIP
switch
Speed Parity
1
Note
2 3 4 5 6 7 8
4800bps
None
○
-
-
-
-
-
-
-
Even
○
-
-
○
-
-
-
-
Odd
○
-
-
-
○
-
-
-
9600bps
None
○
○
-
-
-
-
-
-
Even
○
○
-
○
-
-
-
-
Odd
○
○
-
-
○
-
-
-
19200bps
None
○
-
○
-
-
-
-
-
Even
○
-
○
○
-
-
-
-
Odd
○
-
○
-
○
-
-
-
38400bps
None
○
○
○
-
-
-
-
-
Even
○
○
○
○
-
-
-
-
Odd
○
○
○
-
○
-
-
-
○
: ON,
-
: OFF
Note) DIP switch 1 invalid at 442A-E2.
●
Upright printing/Inverted printing setting
At delivery
DIP switch
1 2 3 4 5 6 7 8
-
-
-
-
-
-
-
-
○
: ON,
-
: OFF
DIP
switch
6
Upright
printing
-
Inverted
printing
○
○
: ON,
-
: OFF
12345678
ON
OFF