CAUTION

Do not scratch, fold, twist, make 

alterations, or bundle the cable, or  

use it as a lifting device.  

The cable 

may be damaged, which may 

cause electrical leakage, short-

circuit, electrical shock, or fire .

Be sure to provide a ground wire  

securel y. Do not connect the 

ground wire to a gas pipe, water  

pipe, lightening rod, or telephone 

ground wire. 

Improper grounding  

could cause electrical shock.

Do not use the cabtyre cable, power

plug, or power outlet if it is damaged 

or it is not closely fitted. Connect  

every conductor of the cabtyre cable 

securely to the terminals.  

Failure to  

observe this can lead to electrical  

shock, short-circuit, or fire .

Install the discharge pipe securely 

so that no water leakage may 

occur. In addition, It is suggested to  

provide a stand-by pump in case of  

flooding. 

Failure to do so may 

result in damage to nearby walls, 

floors, and other equipment .

When the product will be carried by  

hand, decide the number of persons 

considering the mass of the product. 

When lifting up the product, do 

not attempt to do it by simply 

bowing from the waist. Use the 

knees, too, to protect your waist .

This pump is neither dust-proof nor  

explosion-proof. Do not use it at a 

dusty place or at a place where 

toxic, corrosive or explosive gas is  

present. 

Use in such places 

could cause fire or explosion.

If a hose is used for the discharge 

line, take a measure to prevent the 

hose from shaking.  

If the hose 

shakes, you may be wet or  

injured.

Prevent a metallic object or dust  

from sticking to the power plug.  

Adhesion of foreign object to the 

plug could cause electrical  

shock, short-circuit, or fire .

CAUTION

WARNING

Never try to operate the pump if 

somebody is present in the pump 

sump. 

If an electrical leakage 

occurs, it can cause electrical  

shock.

When changing power connection is  

needed to correct the direction of  

rotation, be sure to turn of f the 

power supply (earth leakage circuit 

breaker, etc.), and perform the work 

after making sure that the impeller 

has stopped completel y. 

Failure to  

do so may lead to electrical  

shock, short-circuit, or injury .

Never start the pump while it is  

suspended, as 

the unit may jerk  

and could lead to injury .

When inspecting the pump, be sure 

to turn off the power supply (earth  

leakage circuit breaker , etc.) so that  

the pump may not start acciden -

tally.

 Failure to do so may lead to  

a serious accident .

Do not operate the product under  

any voltage other than described 

on the nameplate with the voltage 

variation limit within ±10%. If it is  

operated with a generator , it is 

strongly suggested not to operate 

other equipment with the same 

generator. 

Failure to observe  

this caution may cause 

malfunction and breakdown of  

the product, which may lead to  

electrical leakage or electrical  

shock.

Do not touch the product with bare 

hands during or immediate after 

the operation, as the product may 

become very hot during operation.  

Failure to observe this caution 

may lead to be burned.

Do not use the product in a liquid 

other than water. 

Use in oil, salt 

water or organic solvents will 

damage it, which may lead to  

electrical leakage or electrical  

shock.

Do not run the product dry or  

operate it with its valve (sluice or  

gate valve) closed, as 

doing so 

will damage the product, which 

may lead to electrical leakage or  

electrical shock.

For water 

only

Rated

Voltage

STOP

OFF

OFF

Summary of Contents for AquascapePro 29495

Page 1: ...w aquascapeinc com 1 www aquascapeinc com 801172003619 B 10174 1 Waterfall and vault water pump For Model 8 PN Item 29495 I N S T R U C T I O N S M A I N T E N A N C E 8 PN 5500 Solids Handling Pond P...

Page 2: ...US 1 866 877 6637 CAN 1 866 766 3426 www aquascapeinc com 2 8 PN 5500 Solids Handling Pond Pump Aquascape 3 6 7 9 11 13 14 16 18...

Page 3: ...hat is included under CAUTION may at times lead to a more serious problem In either case the categories pertain to safety related items and as such must be observed carefully WARNING CAUTION NOTE Expl...

Page 4: ...foreign object to the plug could cause electrical shock short circuit or fire CAUTION WARNING Never try to operate the pump if somebody is present in the pump sump If an electrical leakage occurs it...

Page 5: ...d parts consult with the dealer where it was purchased or Aquascape representa tive Improper repairs can result in electrical leakage electrical shock fire or water leakage Test operation STOP OFF OFF...

Page 6: ...US 1 866 877 6637 CAN 1 866 766 3426 www aquascapeinc com 6 Impeller Screwed Flange Oil Cabtyre Cable Air Release Valve Oil Plug Strainer Pump Casing Mechanical Seal Oil Casing Oil Lifter...

Page 7: ...om 7 Note Note Aquascape Aquascape Aquascape Quick step guide Operation Manual Solids Handling Pond Pump Model Serial Number DOM Y M Bore 2 Input Watts 1000 Volts 115 AMP 9 2 PH 1 Hz 60 Pole 2 Ins E 0...

Page 8: ...gas concentration should be below 0 1 ppm Note The concentration over 0 1 ppm may cause the pump to corrode Shaft Seal Double Mechanical Seal Bearing Shielded Ball Bearing Specifications Dry Type Subm...

Page 9: ...CAN 1 866 766 3426 www aquascapeinc com 9 CAUTION CAUTION Note Note Single Phase CAUTION Models with output of 0 75kW 0 2MPa 2kgf cm2 discharge pressure during use Applicable Pum p Maximum Allowable P...

Page 10: ...US 1 866 877 6637 CAN 1 866 766 3426 www aquascapeinc com 10 CAUTION CAUTION CAUTION...

Page 11: ...NING CAUTION WARNING CAUTION CAUTION Note CAUTION Single Phase L1 Red Brown G Green Green Yellow L2 White Blue L1 L2 G Ground Warning Label If connecting the leads to a control panel connect terminals...

Page 12: ...6637 CAN 1 866 766 3426 www aquascapeinc com 12 Note CAUTION Green White Red Main Coil Ground Aux Coil Operating Capacitor Protector Power Supply Single Phase PN Series Non Automatic Circuit Blue Gree...

Page 13: ...US 1 866 877 6637 CAN 1 866 766 3426 www aquascapeinc com 13 CAUTION Note Note Note WARNING Note CAUTION C W L L W L Ideal is to set pump to...

Page 14: ...US 1 866 877 6637 CAN 1 866 766 3426 www aquascapeinc com 14 WARNING Note flat tip screwdriver Aquascape...

Page 15: ...les office in your area Overhaul Note To overhaul the pump contact the dealer where it was purchased or the Aquascape sales office in your area 4 500 hours or 24 months whichever comes first Changing...

Page 16: ...N 1 866 766 3426 www aquascapeinc com 16 Note Phillips Screwdriver Oil Plug Oil Inlet Packing Model with 0 75kW power output 240 Applicable Model Specified Volume Unit Specified Oil Liquid Paraf fin V...

Page 17: ...ortion Pump Portion Hex Bolt 10 O Ring 3 Impeller 5 Pump Disassembly Diagram O Ring 3 Truss Screw 4 Pump Casing 2 Packing 9 Spring Washer 6 Hex Nut 11 Hex Bolt 7 Screwed Flange 8 Hex Bolt 10 Impeller...

Page 18: ...ace the af fected part 2 Re examine the work plan 3 Check the nameplate and replace the pump 1 The impeller or the pump casing is significantly worn 2 There is a great piping loss 3 A 60Hz pump is use...

Page 19: ...US 1 866 877 6637 CAN 1 866 766 3426 www aquascapeinc com 19...

Page 20: ...US 1 866 877 6637 CAN 1 866 766 3426 www aquascapeinc com 20...

Reviews: