background image

-3-

 PRECAUTIONS DURING MAINTENANCE AND INSPECTION

 PRECAUTION TO POWER OUTAGE

 OTHER PRECAUTION

CAUTION

Do not allow foreign object (pin, 

wire, etc.) to enter the suction inlet 

of the pump. 

Failure to observe 

this caution could cause it to 

malfunction or to operate abnor-

mally, which may lead to electri-

cal leakage or electrical shock.

Do not use the product for hot or 

warm liquid over 40℃, as 

doing so 

will damage the product, which 

may lead to electrical leakage or 

electrical shock.

When the product will not be used 

for an extended period, be sure to 

turn off the power supply (earth 

leakage circuit breaker, etc.). 

Deterioration of the insulation 

may lead to electrical leakage, 

electrical shock, or fire.

OFF

CAUTION

WARNING

Absolutely turn off the power 

supply or disconnect the plug 

before starting maintenance or 

inspection. Do not work with wet 

hands.

 Failure to observe these 

cautions may lead to electrical 

shock or injury.

After reassembly, always perform a test operation before resuming use of the 

product. 

Improper assembly can result in electrical leakage, electrical 

shock, fire, or water leakage.

In case any abnormality (excessive 

vibration, unusual noise or odor) is 

found in the operation, turn the 

power off immediately and consult 

with the dealer where it was 

purchased or Tsurumi representa-

tive. 

Continuing to operate the 

product under abnormal condi-

tions may result in electrical 

shock, fire, or water leakage.

Do not disassemble or repair any 

parts other than those designated 

in the operation manual. If repairs 

are necessary in any other than 

the designated parts, consult with 

the dealer where it was 

purchased or Tsurumi representa-

tive. 

Improper repairs can 

result in electrical leakage, 

electrical shock, fire, or water 

leakage.

Test 

operation

STOP

OFF

OFF

In case of power outage, turn off the power supply.

 The product will resume 

operation when the power is restored, which presents serious danger to 

people in the vicinity.

WARNING

power 

outage

OFF

CAUTION

Never  use  the  product  for  potable  water. 

It  may  present  a  danger  to  human 

health.

Potable 

Water

Summary of Contents for LB-250

Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ......

Page 17: ...facturer will not assume any liability After reading this Operation Manual keep it in a location that is easily accessible so that it can be re ferred to whenever information is needed while operating...

Page 18: ...N may at times lead to a more serious problem In either case the categories pertain to safety related items and as such must be observed carefully WARNING CAUTION NOTE Explanation of Symbols PRECAUTIO...

Page 19: ...ical leakage occurs it can cause electrical shock When changing power connection is needed to correct the direction of rotation be sure to turn off the power supply earth leakage circuit breaker etc a...

Page 20: ...assembly always perform a test operation before resuming use of the product Improper assembly can result in electrical leakage electrical shock fire or water leakage In case any abnormality excessive...

Page 21: ...its voltage and frequency speci cations 2 PART NAMES Cabtyre Cable Mechanical Seal Lubricant Shaft Sleeve V Ring Oil Casing Wearing Impeller Handle Hose Coupling Oil Plug Oil Lifter Strainer Stand Pum...

Page 22: ...to verify the insulation resistance of the motor Note The weight mass given above is the operating weight of the pump itself not including the cabtyre cable Standard speci cations 50 60Hz Bore mm Mode...

Page 23: ...age the cable which may cause a current leakage electrical shock or re CAUTION The rope for suspending the pump during its installation must be of a thickness that accommodates the weight of the pump...

Page 24: ...connect the ground wire to a gas pipe water pipe lightning rod or telephone ground wire Improper grounding could cause electrical shock Connecting the Power Plug WARNING Before inserting the power plu...

Page 25: ...or The pump is equipped with a built in motor protector circle thermal protector If a current overload or overheating occurs under the symptoms given below the pump will stop automatically to protect...

Page 26: ...s accident involving injury 4 When using a generator as much as possible avoid operating the pump in conjunction with other types of equipment COUNTERMEASURE Interchange any two of the three wires des...

Page 27: ...the pump to the pipe and submerge it in water 4 Operate the pump for a short time 3 to 10 minutes and perform the following checks Using an AC ammeter clamp measure the operating current at the phase...

Page 28: ...Refer to section Oil Inspection and Change Procedures below for further detail Interval Monthly Daily Semi yearly Inspection Item Yearly Once every 2 to 5 years Measuring the operating current Measuri...

Page 29: ...and drain the oil completely Pour a speci ed volume of oil into the oil ller inlet Note The drained oil must be disposed of properly to prevent it from being released into the sewer or rivers The pack...

Page 30: ...the disassembly and reas sembly of the sealing portion i e mechanical seal and of the motor require a special ized facility including vacuum and electrical test equipment For these operations con tac...

Page 31: ...e liner im peller and pump casing after removing debris from them such as sand 2 Mount the v ring onto the outside of the shaft sleeve as shown in the drawing When doing so do not apply oil or other l...

Page 32: ...e block under the pump to prevent the pump from drawing in excess mud 1 Foreign matter is wedged in the impeller causing the motor protector to trip 2 The voltage is too low 3 A 50Hz unit is used at 6...

Reviews: