-2-
CAUTION
• Do not scratch, fold, twist, make
alterations, or bundle the cable, or
use it as a lifting device. The cable
may be damaged, which may
cause electrical leakage, short-
circuit, electrical shock, or fire.
• When transporting or installing the pump,
attach a wire rope or chain firmly to the
eyebolt. Do not under any circum-
stances install or transport the pump
by suspending it from the cabtyre
cable. The cable may be dam-
aged, which may cause electrical
leakage, electrical shock, or fire.
• Let the unit suck minimum amount of sand
or mud. When the pump is to be installed
on a soft foundation, mount it on a
concrete block or the like to prevent
it from being submerged in sand.
Damage resulting from abrasion
may bring about electrical leak-
age or electrical shock.
• Provide a secure ground. Do not connect
the grounding wire to a gas pipe, water
pipe, lightning rod, or telephone
ground line. Improper grounding
may lead to electrical shock.
• This product is neither dust-proof
nor explosion-proof. Do not use it
at a dusty place or at a place
where corrosive, toxic or explosive
gas presents or may be gener-
ated. Use in such places could
cause fire or explosion.
• If a hose is used for the discharge
line, take a measure to prevent the
hose from shaking. If the hose
shakes, you may be wet or
injured.
• Do not use the cabtyre cable if it is
found to be damaged. Connect the
cabtyre cable securely to the
terminals. Failure to observe this
can lead to electrical shock,
short-circuit, or fire.
• Install the discharge piping
securely so that no water leakage
may occur. Failure to do so may
result in damage to nearby walls,
floors, and other equipment.
PRECAUTIONS DURING TEST OPERATION AND OPERATION
CAUTION
WARNING
• Never start the pump if somebody
is present in the pump sump. If an
electrical leakage occurs, it can
cause electrical shock.
• When inspecting the pump, be
sure to turn off the power supply
(earth leakage circuit breaker, etc.)
so that the pump may not start
accidentally.Failure to do so may
lead to a serious accident.
• Never start the pump while it is
suspended, as the unit may jerk
and lead to injury.
• Do not operate the product under any
voltage other than described on the
nameplate with the voltage tolerance limit
within ±5%. If it is operated with a
generator, it is strongly suggested not to
operate other equipment with the
same generator. Failure to observe
this caution may cause malfunc-
tion and breakdown of the prod-
uct, which may lead to electrical
leakage or electrical shock.
• Do not touch the product with bare
hands during or after the operation,
as the product may become very
hot during operation. . Failure to
observe this caution may lead to
burn.
• Do not use the product in hot or
warm liquid over 40°C, as doing so
will damage the product, which
may lead to electrical leakage or
electrical shock.
• Do not use the product in a liquid
other than water. Use in oil, salt
water or organic solvents will
damage it, which may lead to
electrical leakage or electrical
shock.
• Do not run the product dry or
operate it with its maximum head,
as doing so will damage the
product, which may lead to
electrical leakage or electrical
shock.
• Check that the motor rotates in
the correct direction of rotation.
Operating in the wrong direction
may damage the pump, which
may cause electrical leakage
or electrical shock.
water only
rated
voltage