-6-
• Do not use this pump in liquids other than water, such as oil, salt water, or
organic solvents.
• Use with a power supply voltage tolerance within ± 5% of the rated voltage.
• Do not use in water temperatures outside the range of 0 ~ 40°C, which can
lead to failure, electrical leakage or shock.
• Do not use in the vicinity of explosive or flammable materials.
• Use only in fully assembled state.
Consult your local dealer or Tsurumi representative before using with any liquids other than those indicated
in this document.
CAUTION
Note:
4 INSTALLATION
Checks to make before installation
Use the megohmmeter to measure the motor insulation resistance between the cabtyre cable plug tips and
ground.
The reference insulation resistance (20MΩ or greater) is the value when the pump is new or has been
repaired. For the reference value after installation, see below at Maintenance and Inspection(p.11).
Note:
Preparing for installation
Before installing the pump at a work site, you will need to have the following tools and instruments ready:
• Insulation resistance tester
• AC voltmeter
• AC ammeter (clamp-on type)
• Bolt and nut tighteners
• Power supply connection tools (screwdriver or box wrench)
Please read also the instructions that come with each of the test instruments.
Note:
Maximum allowable water pressure
Do not use at greater than the water pressure shown in the table.
CAUTION
Model
JIS20K
0.5MPa(5kgf/cm
2
)
JIS10K
Flange Specification
LH6110
JIS20K
LH4110W
LH8110
Maximum water pressure
Standard specifications (50/60Hz)
The weight (mass) given above is the operating weight of the pump itself, not including the cabtyre cable.
Note:
Model
107/114 (351/374)
Bore
mm
2.0 (528)
1270
LH4110W
3
Star Delta
110
100
3.0/2.7 (793/713)
177/184 (581/604)
6.5 (1717)
1210
1210
LH6110
3
Star Delta
110
110
150
200
LH8110
3
Star Delta
216/230 (709/755)
Starting Method Output
kW
Max.CAPACITY
m
3
/min(GPM)
Weight
kg
Max.HEAD
m (feet)
Phase
Precautions in installation
When installing the pump, pay close attention to its center of gravity and
weight. If it is not lowered into place correctly, it may fall and be damaged or
cause injury.
Do not under any circumstances install or move the pump by suspending
it from the cabtyre cable. The cable may be damaged, causing electrical
leakage, shock, or fire.
WARNING
CAUTION