Beijing TT Aviation Technology Co., Ltd.
Add: No.1 TTA Building, Niantou Industrial Park ,Changping District,Beijing, China
www.ttaviation.com
37
②
Operate the the rudder to control the direction;
③
Adjust point A: while the drone moving from point B to Point A, push up the Elevator
stick to make point A 1m closer to point B, pull down the Elevator stick to make
point A 1m away from point B.
④
Adjust point B:while the drone moving from point A to Point B, push up the Elevator
stick to make the point B 1m away from point A, pull down the Elevator stick to
make point B 1m closer to point A.
5) Shut Down and Quit
①
When set the “no pesticide” action to self-hovering or return,in AB mode this
function still works.
②
When set the “low battery” action to return,in AB mode the this function still works.
③
After the spraying work is done,AB mode can be shut down by switching into
altitude mode.
6) To return to the breakpoint,after broke the AB mode route automatically or manually..
Filling the pesticide in the tank and taking off, then switch E (flight mode)to AB mode
directly ,the drone would return right to the breakpoint.
2. Delete Point A and B
Move stick F (AB mode) for 4-5 times rapidly,LED alternately flash red green and
yellow,AB mode removed.
Without removing last AB point, user can not set new AB
point.
3. Set the Interval Width
From the software->Flight parameters to set the spraying width and working speed
Attention:
1) Be sure to start AB mode within turning on the pump.
2) Be sure it is at least 10 meters away from point A to point B.
3) Every time recording point A and B,be sure to wait until the drone self-hovering
steadily in GPS mode.