Beijing TT Aviation Technology Co., Ltd.
Add: No.1 TTA Building, Niantou Industrial Park ,Changping District,Beijing, China
www.ttaviation.com
18
4.2.1 Remote Controller Calibration In GCS
Two kinds of calibration ways:
①
Calibration In GCS. To keep synchronization with the Info of flight controller
②
RC Hardware Calibration. To calibrate the channels of RC itself. (more details at
chapter 5.3 )
Remote controller calibration:click the button
READ
to get the data as following figure.
1) Start to calibrate:connect copter with GCS,click
RC CHANNEL
,move the stick to
maximum and minimum position 4 to 5 times.
2) Stop calibration:click Finish after calibration. Then check the channel status.
3) Normal or reverse setting of remote controller is set to check whether it’s right
4.2.2 IMU Calibration
Leave the copter in a horizontal position,click the button
ACCELEROMETER
,LED will
flash in red,green,yellow alternately,LED
green
means successful calibration,data will be
stored by restart.