PD-20001-R1
Stagetracker II User Manual
20
In these tables, h
eff
is the RE height above the tag.
Table 1 Usable area, x-axis:
∆𝑥
1
+ ∆𝑥
2
ℎ
𝑒𝑓𝑓
[m]
α
[deg]
1.5
2
3
4
5
6
0
3.6
4.8
7.2
9.5
11.9
14.3
10
3.9
5.1
7.7
10.3
12.9
15.4
20
5.0
6.6
10.0
13.3
16.6
19.9
30
9.1
12.1
18.1
24.1
30.2
36.2
40
Inf
Inf
Inf
Inf
Inf
Inf
50
Inf
Inf
Inf
Inf
Inf
Inf
Table 2 Usable area to the left of the RE:
∆𝑥
1
ℎ
𝑒𝑓𝑓
[m]
α
[deg]
1.5
2
3
4
5
6
0
1.8
2.4
3.6
4.8
6.0
7.2
10
1.3
1.7
2.5
3.4
4.2
5.0
20
0.9
1.2
1.7
2.3
2.9
3.5
30
0.5
0.7
1.1
1.5
1.8
2.2
40
0.3
0.4
0.5
0.7
0.9
1.1
50
0.0
0.0
0.0
0.0
0.0
0.0
6.4
Network topology
The beacon controlling the Tags is located onboard the Stagetracker II™ Core unit therefor the unit must
be located close to
the tracking area.
Figure 22 Stagetracker II™ network topology with two RadioEye configuration