PD-20001-R1
Stagetracker II User Manual
23
3.
Select Use the following IP address, and enter the following.
IP address: 194.168.100.xxx (in the range of 2-254, except
the IP address of the Stagetracker II™ Core
)
Subnet mask: 255.255.255.0
4.
Click OK and then Close.
Figure 17 Internet Protocol version 4 (TCP/IPv4) Properties window
8.2.2
Downloading and i
nstalling the Stagetracker II™ Controller
1.
Download the Stagetracker II™ Controller software to your
computer
from the Stagetracker II™ Core
web panel. To access the web panel, go to the IP address found on the touchscreen display on the
Stagetracker II™ Core in your web browser of choice.
2.
Locate the downloaded Stagetracker II™ Controller installer and run it. Enter
user credentials if
prompted.
8.2.3
Connecting to the Stagetracker I
I™ system
Make sure that the
Stagetracker II™
Controller software and the
Stagetracker II™ Core software versions match each other,
see below. TTA will assist on the latest matching software on email request: support@tta-sound.com.
The
Stagetracker II™ Core software version is found on the touchscreen display on the front panel of the unit.
Example of matching software versions:
Stagetracker II™ Controller software:
Stagetracker II Controller 2.6.1.msi
Stagetracker II™ Core software:
Stagetracker_R2.6.1rcxx.tta
The Stagetracker II™ Controller version that matches the Stagetracker II™ Core software can be found at the web panel of
the Stagetracker II™ Core.
1.
Open the installed Stagetracker II™ Controller on your computer and enter the
IP address found on
the touchscreen display on the Stagetracker II™ Core.