6
ELECTRICIAN’S MULTIMETER
GENERAL SPECIFICATIONS
Max voltage between input terminal and ground: please refer to the technical index for more
details.
20A terminal: 20A 250V fast-acting fuse ( 5x 20mm)
mA/µA terminal: 600mA 250V fast-acting fuse ( 5x20mm)
Display count: 6000
Max capacitance: 100mF
Range: Manual
Polarity: Auto
Refreshes 2-3 times/s; “OL” appears when over-range
Operating temperature: 0°C~40°C (32°F~ 104°F )
Storage temperature: -20°C~60°C (-4°F- 140°F)
Relative humidity: 0°C ~ below 30°C <75%, 30°C~40°C <50%
Operating altitude: 0-2000m
Battery: AAA 1.5V x 4
Low battery indication: LCD displays “
” symbol
EMC:
a. RF field {1V/m): overall accuracy= specified a 5% of range
b. RF field (>3V/m): no specified calculation
EXTERNAL OVERVIEW
3.
4.
5.
2.
1.
11.
10.
13.
12.
7.
8.
9.
6.
1. Auto backlight
sensing window
2. LCD screen
3. Functional buttons
4. Function selector
5. Input terminals
6. Hook
7. Multifunctional
test lead slot
8. Flashlight
9. Battery cover screw
10. Case holder
11. NCV sensing part
12. Transistor test ports
13. Audio/visual
alarm indicator