KabuKlip
Operating Manual v1.2 - Page 12/17
www.tuchler.net
June 2014
8.
Control of the KabuKlip controller
The following control and display elements are provided on the KabuKlip controller:
Status LED
LIGHT button
Master LED
Key-operated
switch
Release button
"Fire"
8.1.
Control sequence:
After the DMX addresses and the master/slave relationship have been set, the
controller is ready for use. "Master" operating mode is indicated by the orange
LED lighting up.
After the power supply is connected, the status LED flashes red if the key -
operated switch is set to "Armed".
If this is the case, set the key-operated switch to "Disarmed" and press the LIGHT
button. The LED will switch from red to green.
If the status LED lights up blue, set the key-operated switch to "Disarmed" and
press the LIGHT button. The LED will switch from blue to green. This procedure
must be repeated after every drop.
Pressing the LIGHT button switches the integrated LED clamp lights in the
KabuKlip release units on and off respectively.
If the status LED lights up green, the solenoids are active and the material to be
dropped (fabric/foil) can now be clamped.
a.
Press the armature plate on the solenoids to do this.
b.
Set the required distance with the adjusting screw, or
c.
Use the adjusting screw to clamp the item to be dropped.