2.
Important safety and operating information
Always observe the following 12 points.
These are only an initial introduction and are not a substitute for reading and following
the operating manual or the manufacturer's instructions.
1.
Remember that dropped loads can cause injuries and damage property.
2.
The drop zone must always be cordoned off when the system is loaded, especially
during assembly and when attaching the load.
3.
Make sure the release unit is secured against unauthorised operation.
4.
Make sure the release unit is secured against a power loss:
install an emergency power supply of some kind (e.g. UPS).
Take appropriate technical and organisational measures to secure the system so
that the connecting and power cables cannot be unplugged.
The KabuKlip units will open and drop their load in the event of a power loss.
5.
TÜCHLER hereby reject all liability for damage caused by falling objects
regardless of whether this was intentional, unintentional or the result of a
malfunction.
6.
The system may only be used when within view and by trained specialist personnel
over 18 years of age (subject to physical and mental suitability).
7.
If operation of the KabuKlip system within the operator's line of sight is not possible
for architectural reasons, the equipment should only be used with the aid of an
additional observer who has an unobstructed view of the system.
8.
Modifications or changes to the design or the electronics require consent in writing
from TÜCHLER Bühnen- & Textiltechnik GmbH, Vienna 22. Failure to obtain this
shall render the guarantee void.
9.
Note that the load capacity of the mounting for the system may be less than the
load capacity of the KabuKlip in individual cases, in which case the latter must be
reduced accordingly by the user. Trouble-free operation is only assured if cables 4
x 1.5 mm² in good condition are used - cables with a smaller cross-section can
overheat and reduce the load capacity.
10.
Observance of the maintenance intervals is essential. The guarantee period will be
terminated if these are exceeded.
11.
Disconnect the power on all poles for any maintenance or repair work.
Remove all loads from the KabuKlip release units before disconnecting the power,
as the KabuKlip units open and drop their loads if no voltage is applied.
12.
The power supply must be disconnected if other kinds of work are being carried
out at the ceiling or piping.