21
TROUBLESHOOTING
•
Barbecue won’t light? Check all gas
connections and that the gas bottle has gas.
•
Ignition is not working? Check the leads are
connected properly and adjust the spark
gap to make sure the gap is 4mm from the
ports on the burner. For Natural Gas it is best
to have the igniter probe just above the
ports on the burners and for L.P. Gas it is best
positioned just below the the ports on the
burners.
•
Check that the ignition leads are connected
properly as the ignition lead might just need
to be firmly connected into either the ignition
probe or the ignition button correctly. The
lead may be damaged also.
•
One of the burners won’t light? Check the
throat of the burner for a blockage, remove
the air mixture cap and gauze on the throat
of the burner and push a screwdriver up it to
clear the blockage.
•
Control knobs are stiff? Remove the knobs
and spray the valve shaft with unceasing
lubricant then oil the shafts of the control
valves and replace the knobs.
TROUBLESHOOTING SOLUTIONS
Check the injector nipple that supplies the gas
to the burner it maybe has a blockage.
Valve injector