920.1044 | 23
6. INTERCOM
■
DESCRIPTION
The 950N2 is capable of communicating with other 950N2
units via an Intercom network connection. This enables
the following modes of operation to be used (KP EVO
menu 2.6.1):
- INTERMODE: a master door from which to set the
operating mode for all the other doors that are connected
to the network.
- INTERLOCK: two single doors, where the opening
of one is subject to the closing of the other and vice versa.
- 2 LEAVES: access consisting of a double leaf.
- 2 INTERLOCK: two interlocked accesses, each
consisting of a double leaf.
------------------------------------------------------------------------------------------------------------------------------------
Every network connected 950N2 should be
programmed for the same Intercom mode.
-----------------------------------------------------------------------------------------------------------------------------------
■
CONNECTION
The units in the network are connected via 3 cascade
connected-wires between the J8 connectors of the
I/O boards
(14).
------------------------------------------------------------------------------------------------------------------------------------
The sequence in which the units are wired is
unimportant, but it is essential that a CASCADE
connection is used.
-----------------------------------------------------------------------------------------------------------------------------------
The 2 DIP switches on the I/O board must be set as
follows:
- On the fIrst and last units of the cascade connection:
both ON.
- On intermediate units (if any): both OFF.
■
ADDRESSING
A unique ID (KP EVO menu 2.6.2) must be assigned to
each 950N2 in the network as indicated below.
------------------------------------------------------------------------------------------------------------------------------------
Do not assign the same ID to more than one
unit in the network.
-----------------------------------------------------------------------------------------------------------------------------------
■
REGISTRATION
After having wired up and assigned an address to each
unit, registration (KP EVO menu 2.6.3), must only be
carried out on the 950N2 that has been assigned ID1.
Summary of Contents for KP evo
Page 1: ...920 1044 KP evo TAP CONTROLLER ...
Page 2: ......
Page 9: ...920 1044 07 ...
Page 10: ...920 1044 08 ...
Page 11: ...920 1044 09 ...
Page 19: ...920 1044 17 G ERRORS ...