background image

3.2

 

System

 

Configuration Recommendation:

OS

Windows 7/8/10 (

)

32&64bit

CPU

Intel Core i5 or better

Memory

USB ports

Support 

USB3.0,USB2.0 

 

 

Connect the camera to the PC. Insert the 

 that comes with the 

camera, copy the software 

"

Mosaic 2.1

. exe 

"

  to the computer. Double click on it 

and follow the [Next] button to finish the installation. After [finish], a software 

shortcut will be created on the desktop.

USB-Stick(or CD)

The software version number, camera model and computer configuration 

information can be obtained from the information in the info menu at the top right of 

the software.

Note: If the camera is connected correctly, the camera device will automatically 

recognize and enter the preview state when the software is turned on. If the “No 

Camera” error appears, it could be the camera is not detected by the PC or the 

driver is not installed properly. Please go to Device Manager to check the camera 

driver installation status.

Windows 7/8/10 (32&64bit)

Intel Core i3 or better

4GB 

 

or more

Camera

USB3.0 Series

USB2.0 Series

 

3.3 Software Installation

Setup-Mosaic 2.1

Welcome to the Mosaic 2.1 Setup 

Wizard

This will install Mosaic 2.1 on your computer.

It is recommended that you close all other applications before

continuing.

Click Next to cuntinue, or Cancel to exit Setup.

Next

Cancel

Go to the Device Manager and check whether the driver is installed properly. If 

there is NO YELLOW FLAG with the camera under Imaging Devices in Device 

Manager, the driver is installed successfully. If there is YELLOW FLAG, you need to 

reinstall the driver.

 

 

Note: When running advanced functions such as "real-time  stitching" or "real-

time EDF", the camera should be used in 64bit OS and the memory is 

recommended to be 8GB or more.

..

..

..

..

..

..

...

...

.

..

..

..

..

..

..

..

Display adapters

Human

 

Interface Devices

IDE

 

ATA /ATAPI

  

controllers

Imaging devices

MI

 

chrome

 

5

 

Pro

Keyboards

Mice and other pointing devices
Monitors

Camera

 

Model

-8-

-7-

4GB or more

Support 

USB3.0,USB2.0 

Double-click the Mosaic 2.1 shortcut        to start the software. 

 

 

When installing 

and starting up the software for the first time, the biological or industrial 

application option box will pop out, select your application direction to enter the 

software. The software will automatically optimize parameter settings based on 

your choice. While using software, the application direction can also be switched 

through [Information] - [Options] - [Microscope] on the right upper part of menu 

bar.

Please

 

select

...

Biology

Industry

Preferences

Language

Microscope

Please

 

select

...

Biology

Industry

X

Summary of Contents for FL

Page 1: ...0 811 Email service tucsen com Landing the official website to leave a message http www tucsen com 3 Please have the following information prepared Camera model and S N product serial number Software version number and system information Description of the problem and any images related to the problem After sales support Copyright Tucsen Photonics Co Ltd All rights reserved ...

Page 2: ...x USB3 0 data cable 2 x 1 x Camera 1 x Software U disk Screws 20MP Resolution Cooling noise reduction Real time 3D noise reduction Real time sharpening Real time stitching Real time EDF USB3 0 1 x Camera 1 x Power 1 x Power adapter 1 x Software U disk 1 x USB3 0 data cable cable 12V 8A 5MP 20MP Resolution Real time stitching Real time EDF USB3 0 Standard lists 1 x Software U disk 1 x USB2 0 data c...

Page 3: ...acket HDMI adapter Note itemsareonlyavailablewhenthecameraispurchasedwiththescreen 2 Camera Interface Description 2 1 FL Cooled Camera USB3 0 2pcs Indicator lights Screw positioning hole Powerswitch USB3 0 Powerinterface Indicator light External trigger interface 2 2 USB3 0 Camera 2 3 USB2 0 Camera When the USB cable is connected one indicator is always on when the software is running another indi...

Page 4: ...n or off to turn on or off the HDMI camera 5 SD card To get faster and more stable data transfer we recommend you to use a Class10 SD card Connect Or Power supply Note Some cameras support USB power supply no need to install additional power supply please refer to whether the power supply accessories are provided in the accessory list 3 1 Camera Installation Camera USB Cable Microscope PC Indicato...

Page 5: ... computer It is recommended that you close all other applications before continuing Click Next to cuntinue or Cancel to exit Setup Next Cancel Go to the Device Manager and check whether the driver is installed properly If there is NO YELLOW FLAG with the camera under Imaging Devices in Device Manager the driver is installed successfully If there is YELLOW FLAG you need to reinstall the driver Note...

Page 6: ...t on the preview pictures Under stable lighting environment move the regional white balance box to any white part of the pictures then adjust size and check Lock White Balance to lock present white balance which will make white balance calibration more accurate After selecting Gray the preview screen will turn into monochrome mode Huerefers to the shade of the color saturation is thepurity of the ...

Page 7: ...t Use File Name A file will be saved with the name TS as default but the name can be customized Customized name time stamp is supported A name can contain up to 64 bytes File format Support JPG TIF PNG DICOM default to TIF and can be checked simultaneously but at least one of them must be chosen Under default status the image file shall be saved to a file folder specified in defined Path user can ...

Page 8: ... the cursor is moved to the left of the screen Capture and Setting icons will appear Click Setting to get the parameter setting menu Calibration Horizontalflip Verticalflip Zoomin Mask Album Compare Back Zoomout Crossline Crosslinewithscale Retina screen Microscope HDMI cable Y power splitter cable 12V2A Power adapter HDMI camera Mouse 14 13 Note Different models of cameras have different function...

Page 9: ...ectable to have the data of perimeter or area 8 Perpendicular Measure the perpendicular length 9 Concentric circles Get the diameters of the two concentric circles 10 Bicircle Get the distance between two circles center points 11 Angle Measure the angle 1 Set the measurement line width color and font color 2 Magnifier On off Switch on off the magnifier Whenthe magnifier is switched on the cursor l...

Page 10: ...surface 6 Use only the original power adapter Ensure the adapter and associated cables are free from items that may cause damage If the power adapter is damaged please contact the supplier for an immediate replacement 17 6 Maintenance 5 Precautions CAUTION Do not disassemble Do not contact water Do not subject the camera to physical shock Immediate repair request Do not disassemble repair or modif...

Reviews: