This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit
contains no user serviceable parts. Only factory service personnel may perform repairs.
Internal battery voltage is 12Vdc. Sealed, lead-acid, 6 cells battery. Connection to any other type of receptacle
other than a two-pole, three-wire grounded receptacle may result in shock hazard as well as violate local
electrical codes.
In the event of an emergency, press the Smart On/Off Button for 4 seconds and disconnect the power cord
from the AC power supply to properly disable the UPS.
Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other
liquid-containing vessels on or near the unit.
This unit intended for installationina controlled environment (temperature controlled, indoor area free of
conductive contaminants). Avoid installing the UPS in locations where there is standing or running water,
or excessive humidity.
Do not plug the UPS input into its own output.
Do not attach a power strip or surge suppressor to the UPS.
Do not attach to non-computer-related items, such as medical equipment, life-support equipment,
microwave ovens, vacuum cleaners, lazer printers or washing machine.
To reduce the risk of overheating the UPS, do not cover the UPS
cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting
appliances such as space heaters or furnaces.
Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
Do not dispose of batteries in a fire as they may explode.
Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. lt may
be toxic.
Attention, hazardous through electric shock. Also with disconnection of this unit from the mains,
hazardous voltage still may be accessible through supply from battery. The battery supply should be
therefore disconnected in the plus and minus pole of the battery when maintenance or service work
inside the UPS is necessary.
Servicing of batteries should be performed by authorized personnel. Keep unauthorized personnel away from
batteries.
A battery can present a risk of electrical shock and high short circuit current. The following precautions
should be observed when working on batteries:
1) Remove watches, rings, or other metal objects from the hands.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or disconnecting batteries terminals.
When replacing batteries, replace with the same number and type of sealed lead-acid battery. The maximum
ambient temperature raling is 40˚C.
This pluggable type A equipment with battery already installed by the supplier is operatar installable and
may be operated by laymen.
During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS
and the connected loads does not exceed 3.5 mA.
The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily
accessible.
SAFETY - WARNING