Tünkers 8-Channel Motor Terminal 

for controlling maximum 8 electronic clamping devices

 

TMI8 V2.1 

 

Subject to technical alterations 

Page -3- 

06/03/2018

 

 

TÜNKERS

®

 

Maschinenbau GmbH  Am Rosenkothen 8 • D-40880 Ratingen  Tel.  02102 4517-0 • Fax 02102 445808  Internet  www.tuenkers.de 

 

1.  Product overview 

 

1.1  Block diagram 

 

XS1

XS2

XE1

XE12

+24V

+24V

RS422

XBE

XBA

XA1

XA8

*
*
*

*
*
*

XS3

3,3V
Interne
Spannung

Ust = +24V
Steuer-
Spannung

Ul = +24V
Last-
Spannung

Initiatoren
Endlagen-
meldung;
Allgemeine
Eingänge

Service
Anschluss
KEBA-Terminal

XBK

Feldbus:
DeviceNet
PROFIBUS-DP
PROFINET-IO
Ethernet-IP

Spanner-
motoren

+24V

+5V

+5V

 

1.2  Brief description 

 
The TMI8 control unit serves for controlling up to 8 electrically operated 
clamping devices via a field bus interface. The device can be selective-
ly controlled via DeviceNet, Profibus-DP, PROFINET IO or Ethernet-IP. 
Next to the initiators for notifying the end positions Close or Open, up to 
8 binary inputs can also be connected. The device can be configured 
and the current operating states can be represented using a hand-held 
terminal. The operating and error states can be displayed on the device 
using the two-digit display. 
 

Connections: 

1 input / 1 output 

 

+24V control voltage 

1 input 

 

 +24V load voltage 

8 inputs  

 

End position sensor Open / Close 

4 inputs  

 

General inputs 

1 input / 1 output 

 

Fieldbus (device variant DeviceNet,  

 

 

PROFIBUS-DP, PROFINET-IO or  

 

 

Ethernet-IP) 

8 outputs 

 

Clamping motors 

1 output 

 

Hand-held terminal 

 
The control is galvanically isolated from the supply. 
 
 

2.  Operating conditions and standards 

 

Safety

 

The safety function is only guaranteed with the TVM8-
Safety 230V or TVM8 Safety 400V connected. 

 

 

Parameter

 

Value

 

 

 

Level achieved 

MTTFd 

Classification: MTTFd = High 

Safe separation 

 

 

 

Load voltage  

PFHD 

 

 

 

 

 

Safe separation  

 

 

 

 

 

 

Load voltage 

 
 
Climate

 

Operation at  

 

0° … 50° C 

Storage at  

 

-

20° … 70° C 

Rel. humidity 

 

up to 80%, no condensation 

Protection category IP54 

Protection category IP54 

Protected against dust in harmful 

 

 

 

amounts, complete contact protection  

 

 

and protection against splash water on all 

 

 

sides 

Service life 

 

10 years 

 
 

Regulations 

EN 61326-1:2013 "Electrical equipment for measurement, control and 
laboratory use - EMC requirements - Part 1: General requirements (IEC 
61326-

1:2012)“  

 
EN 55011:2009 + A1:2010 "Industrial, scientific and medical equipment 
-  Radio-frequency  disturbance  characteristics  -  Limits  and  methods  of 
measurement (IEC/CISPR 11:2009, mo A1:2010)“ 
 

3.  Description of the safety function 

 

The functional safety is guaranteed by the safe switching 
off of the load voltage on the XS3 by the voltage supply 
modules TVM8-Safety 230V or TVM8 Safety 400V.  

 

 
The safety function in the TMI8 includes only the safe separation of the 
load voltage from the other supply voltages. To guarantee the function-
al safety, the TMI8 must always be operated with a TVM8 Safety 230V 
or TVM8 Safety 400V. 
 
 

Summary of Contents for TMI8 V2.1

Page 1: ...ing maximum 8 electronic clamping devices TMI8 V2 1 Subject to technical alterations Page 1 06 03 2018 T NKERS Maschinenbau GmbH Am Rosenkothen 8 D 40880 Ratingen Tel 02102 4517 0 Fax 02102 445808 Int...

Page 2: ...tions and standards 3 3 Description of the safety function 3 4 Structure of the hardware 4 4 1 2 digit 7 segment display 4 4 2 Display LEDs for the fieldbus module 4 4 3 Display LEDs for electric clam...

Page 3: ...put Fieldbus device variant DeviceNet PROFIBUS DP PROFINET IO or Ethernet IP 8 outputs Clamping motors 1 output Hand held terminal The control is galvanically isolated from the supply 2 Operating cond...

Page 4: ...Defective motor driver 14 Initiator error Close Open 16 Deactivation via adjustable current limit values 21 86 Error codes clamp channel 2 8 4 2 Display LEDs for the fieldbus module Green LED B1 B2 B...

Page 5: ...connector input 24V voltage supply control voltage IO Bus and int logic XS2 M12 circular connector 4 pin connector output 24V voltage supply control voltage IO Bus and int logic XS3 M23 circular conne...

Page 6: ...re can be established by both connectors The device TMI 8 PB is equipped with a Profibus interface XBA Output Profibus interface M12 socket 5 pin B coding XBE Input Profibus interface M12 connector 5...

Page 7: ...change initially The status is also visualised on the KEBA terminal As soon as the menu selection or a respective sub menu is se lected on the KEBA terminal the operating mode and the display change t...

Page 8: ...load voltage present 1 Byte 6 8 Reserve 5 1 2 Control program In EB 1 or EB2 the fieldbus master can either trigger an Open com mand or Close command for the respective clamp If the clamp is position...

Page 9: ...of the TMI8 in automatic mode is displayed If the menu selection is selected in the KEBA terminal the TMI8 changes to manual mode When returning to the status display on the KEBA terminal the TMI8 is...

Page 10: ...sulation between control voltage Ust and load voltage UI Insulation voltage min 3750V rpm UL certification in accordance with UL1577 VDE certification in accordance with VDE V 0884 5 10 or EN60747 5 2...

Page 11: ...r EMC base standard Test value Housing Discharging of static electricity ESD Electromagnetic fields Power frequency magnetic fields IEC 61000 4 2 IEC 61000 4 3 IEC 61000 4 8 4kV contact discharge 8kV...

Page 12: ...maximum 8 electronic clamping devices TMI8 V2 1 Subject to technical alterations Page 12 06 03 2018 T NKERS Maschinenbau GmbH Am Rosenkothen 8 D 40880 Ratingen Tel 02102 4517 0 Fax 02102 445808 Intern...

Reviews: