16
Owner
’s manual • Pure Row 8.1
The rowing console does not
illuminate after battery installation.
Possible cause:
Batteries installed incorrectly or need
replacing.
Solution:
• Reinstall batteries in correct position
and try again.
• If the LCD screen fails to illuminate,
try rotating the batteries slightly in the
console.
• If this fails, contact your local service
center.
The rowing console screen
illuminates, but does not register
when rowing.
Possible cause:
Loose or failed connection
Solution:
• Check that the console lead is
connected properly.
• If it is connected then contact your
local service center.
Warranty
The product has a warranty from the
date of delivery (to be documented by
invoice). Further information on warranty
terms can be obtained from your local
dealer. The warranty terms may vary
from one country to another. Damages
caused by normal wear, overloading or
improper handling are excluded from the
warranty. Damages caused by material
or manufacturing faults are covered
by the warranty and will repaired or
replaced at no cost.
Declaration of the
manufacturer
Tunturi New Fitness BV declares that the
product is in conformity with the following
standards and directives: EN 957 (SC),
89/ 336/ EEC. The product therefore
carries the CE label.
by tightening the tension in small
increments and testing until the
correct tension is achieved.
• If the rower handle cannot reach the
end of the seat rail during a rowing
stroke, then the bungee cord is over-
tensioned.
Troubleshooting
Water changes color or becomes
cloudy
Possible cause:
Rower is in direct sunlight or has not had
water treatment.
Solution:
• Change rower location to reduce
direct exposure to sunlight.
• Add water treatment or change
tank water as directed in the water
treatment section of this manual.
Rower belt slipping off belt / bungee
pulley
Possible cause:
Bungee cord not under enough tension.
Solution:
• Tighten bungee cord following the
instructions in “Re-attaching the
rowing belt” - step 8 of this manual.
Front of rower lifts slightly during
vigorous rowing.
Possible cause:
Vertical seat rail tensioning bolt
(M10x150mm) is too loose.
Solution:
• Tighten bolt 1/2 turn and row again.
Tighten as needed until problem
stops.
Over tightening this bolt can damage
the seat rail. Only tighten bolt in small
increments until fault is corrected.