Failure: The water flow through the inlet and the
recirculation pump is less than expected.
Cause: The water inlet has too many elbows,
wrong pipe connection or an excessively small
diameter.
Remedy: The water should be passed into the
aquarium through as few elbows as possible.
The pipe diameter should not fall short of 25 mm
(.98 in.).
Cause: The required head pressure excede the
pumps capacity.
Remedy: Please observe the pump data.
Failure: The recirculation pump blows air
bubbles into the aquarium.
Cause: The water level in the filter system is too
low.
Remedy: The water level regulator does not
operate anymore; check the function of the
Osmolator.
Cause: The oxygen saturation has been exceeded
by strong photosynthesis (algae growth).
Remedy: Bring the aquarium into a better ecological
balance or wait until the start-up phase has been
completed.
Disfonctionnement : Le débit de circulation
provenant de la pompe de reprise est plus faible
que prévu.
Raison : L’amenée d’eau comporte trop de coudes,
de tuyaux ou une section trop faible.
Solution : L’amenée d’eau doit être réalisée avec le
moins de coudes possible. Sa section ne devrait
pas être inférieure à 25mm.
Raison : La hauteur de refoulement est trop
importante.
Solution : Veuillez respecter les données des
pompes.
Disfonctionnement : La pompe de reprise injecte
des bulles d’air dans l’aquarium.
Raisons : Le niveau d’eau dans la filtration est trop
faible.
Solution : La régulation de niveau est hors service,
contrôlez l’Osmolator.
Raison : La saturation en oxygène dissout est
dépassée par l’action de la photosynthèse
(présence d’algues dans l’aquarium).
Solution : L’aquarium doit être amené vers un
meilleur équilibre biologique ou attendez
l’aboutissement de la phase de démarrage.