18
connects drain hose. Connect a water drain hose (included in the pack) to the back of the
device (inner diameter of the connector: 9 mm), the water can be drained continuously.
Check that the hose is properly connected to the drainage hole to avoid accidental water
leakage. The drain hose may not be too long (usually 0.6 m), it should not be positioned
above the level of the drain hole to ensure drainage of the drained water
•
Place the unit on a horizontal and stable surface.
•
Switch off the unit before operating.
Remove the plug of the water drain hole and keep it in a safe place.
Continuous drainage outlet
•
Securely and properly connect the drain hose and make sure it is not obstructed.
•
Place the outlet end of hose into a drainage hole or bucket and ensure that water can
freely drain out of the unit.
•
Do not submerge the end of hose into water; otherwise it can cause "Air Lock" in the
hose.
To avoid water spillage:
As the negative pressure of condensate drain pan is large, tilt the drain hose downwards
toward the floor. It is appropriate that the degree of inclination should exceed 20 degrees.
Straighten the hose to avoid bending.
E.
ANTI-FROST FUNCTION
This function will be activated when the ambient temperature falls below 16°C. The display
will show „P1“. It will be activated for a period of 8 minutes every 38 minutes between
2-12°C. It will also be activated for a period of 5 minutes every 60 minutes between
12-16°C.