background image

Turbo air warrants to the original purchaser of every new Turbo air refrigerated unit, the cabinet and all parts thereof, to be free

from defects in material or workmanship, under normal use and service, for a period of two (2) year from the date of original
installation or 27 months after shipment date from Turbo air , whichever occurs first.

Any parts covered by this warranty that are examined and determined by Turbo air to have been defective within two (2) year of

original installation or twenty seven (27) months after shipment date from manufacturer, whichever occurs first, shall be 
repaired or replaced as stated below. Turbo air shall be deemed to have fully complied with its obligation under the foregoing 
warranties by electing either one of the following procedures, at the sole discretion of Turbo air.

1. Furnishing a replacement part, freight collect, in even exchange for the returned part, freight collect.
2. Receiving the defective part, freight collect; repairing it; and returning it, freight collect.

In addition to the (2) two year warranty stated above, Turbo air warrants its hermetically and semi-hermetically sealed

compressor to be free from defects in both material and workmanship under normal use and service for a period of three (3)
additional years from the date of original installation but not to exceed five (5) years and three (3) months after shipment from
manufacturer.

Compressors determined by Turbo air have been defective within this extended time period will, at Turbo airʼs option, be either

repaired or replaced with a compressor or compressor parts of similar design and capacity.

The three (3) year extended compressor warranty applies only to hermetically and semi-hermetically sealed parts of the

compressor and does not apply to any other parts or components, including, but not limited to, cabinet, paint finish, temperature
control, refrigerant, metering device, driers, motor starting equipment, fan assembly any other electrical component, etcetera.

The five year compressor warranty detailed above will be voided if the following procedure is not carefully adhered to:

1. This system contains R134A refrigerant and polyol ester lubricant. The Polyol ester lubricant has rapid moisture absorbing

qualities. If long exposure to the ambient conditions occur, the lubricant must be removed and replaced with new. Listed below
are the approved lubricants for the Tecumseh compressors.

1 ICI-Emkarate RL 184
2 Emery-2927-A
3 Mobile Artic 22A

Failure to comply with recommended lubricant specification will void the compressor warranty.

2. Dryer replacement is very important and must be changed when a system is opened for servicing. dryer must be used with XH-

9 desiccant.

3. Micron level vacuums must be achieved to insure low moisture levels in the system. 500 microns or lower must obtained.

MANUFACTURING COMPANY

TWO YEAR WARRANTY

ADDITIONAL THREE YEAR COMPRESSOR WARRANTY

134A(404A) COMPRESSOR WARRANTY

Summary of Contents for MUF-28

Page 1: ...tion and Operation Manual CAUTION PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Please read this manual completely before attempting to install or operate this equipment REFRIGERATOR MUR 28 MUR 36 MUR 48 MUR 60 MUR 72 REFRIGERATOR MUF 28 MUF 48 MUF 60 www turboairinc com ...

Page 2: ...R REFRIGERATOR MODEL COMP H P V Hz REFRIGERANT AMPS WEIGHT MUR 36 1 4 115V 60Hz R 134A 6 6A 199lbs MUR 48 1 3 115V 60Hz R 134A 6 5A 246lbs MUR 28 1 5 115V 60Hz R 134A 3 3A 163lbs MUR 72 1 2 115V 60Hz R 134A 9 9A 352lbs MUR 60 1 3 115V 60Hz R 134A 8 9A 282lbs UNDERCOUNTER FREEZER MODEL COMP H P V Hz REFRIGERANT AMPS WEIGHT MUF 48 1 2 115V 60Hz R 134A 8 3A 246lbs MUF 28 1 3 115V 60Hz R 134A 5 3A 163...

Page 3: ...LLATION OF CASTERS 1 Screw the caster in rear side and the caster brakes in front side by using caster wrench 2 Use the caster shims to level the cabinet if necessary by inserting them to stems of the casters ...

Page 4: ... In damp season when the drain water overflow the drain pan remove the drain pan and pour the water away And then set the drain pan back up as below drawing please Model MST 28 MST 28 12 MUR 28 MUF 28 MST 28 MST 28 12 MUR 28 MUF 28 ...

Page 5: ...5 HOW TO CLEAN THE PAN SUPPORTER 1 Remove the Guide Pans and Pans Then pull out the Pan Supporter Clean the pan supporter and reinstall in place MODEL MUR 28 MUR 36 MUR 48 MUR 60 MUR 72 ...

Page 6: ... strong enough to support the total weight of the cabinet and contents 3 DO NOT PLACE NEAR HEAT Be sure to avoid hot corners and locations near stoves High ambient temperature will make much lower cooling efficiency 4 INDOOR USAGE ONLY Be sure to install this unit indoor so it will not get wet from the rain 5 STABILIZING Make sure the unit is installed in a stable condition with the front wheels l...

Page 7: ...2 RE STARTING If disconnected wait 5 minutes before re starting Before cleaning turn unit off at power switch 1 CLEANING THE INTERIOR AND EXTERIOR The interior and exterior of the unit can be cleaned using warm water with soap Do not use an abrasive cleaner because it will scratch the surface 2 COMPRESSOR AND CONDENSER Be sure to keep the condenser coil must be free of dust because of cooling effe...

Page 8: ...trol is Normal 3 Set toward Cool for higher temperature and Cold for lower temperature 4 The thermostat controls compressor s on off by sensing inside temperature If thermostat knob is pointing at OFF compressor and condenser fan motor would not run Keep unit unplugged if not in use for a long period of time REFRIGERATORS ...

Page 9: ...Reversible Instruction For MUR 28 MUF 28 only 1 DOOR DOOR TOP HINGE BOTTOM HINGE SPRING BAR 4 DOOR BUSHING 3 mm DOOR BUSHING 5 mm DOOR BUSHING 2 TOP HINGE BOTTOM HINGE 3 SPRING BAR 一 MAIN COMPONENTS INSTRUCTION ...

Page 10: ...8 only UNIT COVER CAP 二 CHANGE REVERSIBLE DOOR MST 28 711 S MUR 28 MUF 28 6 UNIT COVER CAP 1 Unscrew the top hinge 4 Unscrew the screws located on right of bottom hinge 5 M5 BOLT M6 BOLT 2 Take apart top hinge from unit 3 Lift the door then remove it ...

Page 11: ...door bushing from right top side of door 4 Take apart door dushing from the right bottom side of door 3 Screw the screws located on left of bottom hinge 7 Take apart unit cover cap from the left top side of door 8 Take off unit cover cap from the left top side of door then install it in the right side of door hole ...

Page 12: ... screw the top hinge follow the arrow 9 Put spring bar into the left of door 14 Follow the arrow while you open the door 13 Fix the top hinge with screwer 10 Assemble the door bushing 3mm in the left top position of door 11 Install the door bushing 5mm in the left bottom side of door ...

Page 13: ...correctly The backside of the unit is too close to the wall The tray is not in the correct position High moisture air can produce dewdrops during rainy seasons The door is opened too frequently or left open too long Damp food is stored The door is bent The unit is not level The door gasket has come out Turn the temperature dial to a warmer colder setting Check the power cord to make sure the unit ...

Page 14: ...ater Household and industrial cleaners are the worst type of chlorides to use 8 step that can help prevent rust on stainless steel 1 Using the correct cleaning tools Use non abrasive tools when cleaning your stainless steel products The stainless steel s passive layer will not be harmed by soft cloths and plastic scouring pads Step 2 tells you how to find the polishing marks 2 Cleaning along the p...

Page 15: ...ter to wipe standing cleaning agents and water as soon as possible Allow the stainless steel equipment to air dry Oxygen helps maintain the passivity film on stainless steel 7 Hydrochloric acid muriatic acid should never be used on stainless steel 8 Regularly restore passivate stainless steel Recommended cleaners for certain situation environments of stainless steel A Soap ammonia and detergent me...

Page 16: ...ter shipment from manufacturer Compressors determined by Turbo air have been defective within this extended time period will at Turbo airʼs option be either repaired or replaced with a compressor or compressor parts of similar design and capacity The three 3 year extended compressor warranty applies only to hermetically and semi hermetically sealed parts of the compressor and does not apply to any...

Page 17: ...suse accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLIED OR STATUTORY EXCEPT THE TWO 2 YEAR WARRANTY AND THE ADDITIONAL THREE 3 YEAR COMPRESSOR WARRANTY AS DESCRIBED ABOVE THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES INCLUDING IMPLI...

Page 18: ... lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A620 copper drier or better is highly recommended 3 Micron level vacuums must be achieved to insure low moisture levels in the system 500 microns or lower must be obtained 4 When compressor is grounded suction drier and 620 dri...

Reviews: