MAINTENANCE & CLEANING

1. Turn off unit at power switch. Disconnect power to unit.

2. Remove rear grill.

3. Clean condenser by either brushing off with stiff wire brush or vacuuming with

 

wet/dry vacuum. Condenser is black and looks like a radiator. This should be

 

cleaned every month or as necessary. Keeping clean allows for maximum

 

cooling of unit and long life of compressor.

CONDENSER COIL

Load Line

SIDE DRAW

“If food is placed above the load. It will not be adequately refrigerated.

Please do not load food above load line.”

Summary of Contents for TCB-5R

Page 1: ...ses Bakery Cases Installation and Operation Manual CAUTION PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Please read this manual completely before attempting to install or operate this e...

Page 2: ...AGING MATERIAL 4 LIGHTS 4 SHELVES 4 ELECTRICAL INFORMATION 5 WIRING DIAGRAM 6 OPERATING INSTRUCTIONS 7 8 FRONT CURVED GLASS 9 MAINTENANCE CLEANING 10 11 TROUBLE SHOOTING 12 WARRANTY MODEL COMP H P V H...

Page 3: ...nce 86 inch at the top 20 inch at the rear and 12 inch at the cash inside CAUTION Damage to case and glass can result if pushed on Do not push curved glass end glass doors or door frames Do not place...

Page 4: ...shelves in desired position front glass must be open and rear doors removed Remove doors by lifting upwards and then out of bottom track one at a time Put doors in a safe location Lift front glass up...

Page 5: ...cian Electrical data is located next to electrical junction box see drawing The Bakery Case comes with a power cord Cord is 9 8 feet long The plug is a Improper electrical connections can result in se...

Page 6: ...6 WIRING DIAGRAM TCB 5R...

Page 7: ...LS 5 The thermostat controls compressor s on off by sensing inside temperature THERMOMETER Display changes temperature approximately every two second NOTE Before placing goods to Bakery Case wait for...

Page 8: ...light not work To remove light there is two lamp holders one at each end of light One has a spring in socket Push light toward spring loaded lamp holder till other end of light pops out of other lamp...

Page 9: ...trained personnel should lift curved glass Under normal use hinges will last many years If any of the following problems occur please call Customer Service a Front curved glass closed rapidly b Front...

Page 10: ...sanitized Bakery Case Procedure may have to be done more than once a week if necessary 1 Clean front glass with window cleaner 2 Clean exterior with warm soapy water Wipe down with damp cloth 1 Remove...

Page 11: ...brush or vacuuming with wet dry vacuum Condenser is black and looks like a radiator This should be cleaned every month or as necessary Keeping clean allows for maximum cooling of unit and long life of...

Page 12: ...kery Case Unit should be between 38 and 42 degrees 5 Check that air is flowing inside front of Bakery Case If there is no air flow or air is felt on only one side this is due to anti moisture fans are...

Page 13: ...er shipment from manufacturer Compressors determined by Turbo air have been defective within this extended time period will at Turbo air s option be either repaired or replaced with a compressor or co...

Page 14: ...suse accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLI...

Page 15: ...R404A or R134a refrigerant and polyol ester lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opene...

Reviews: