background image

11

Turbo air

1. LOCATION -

 Allow adequate space and install the refrigerator on a firm, and

 level 

floor. If the appliance is not level, there may be unusual noises and poor cooling 

performance.

2. GOOD AIR CIRCULATION -

 Be sure to avoid any partition and object which may 

stop the air flow and that air space is allowed to flow the rear and/or sides of the unit 

between the refrigerator and the back wall. Insufficient space causes the noise of 

vibration, inefficient refrigeration, damage to the refrigeration system, and the waste 

of electricity. (Turbo Air recommends that the rear of the unit would be no less than 5 

inches from the wall)

3. PLACE ON STRONG FLOOR -

 Be sure that the floor of which the unit is to be 

installed is strong enough to support the total weight of the cabinet and any other 

contents, before starting the installation.

4. DO NOT PLACE NEAR HEAT -

 Be sure to avoid hot corners and other locations 

such as near stoves. High ambient temperature will make much lower cooling 

efficiency.

5. INDOOR USAGE ONLY - 

Be sure to install this unit indoor only. It should prohibit 

getting wet from the rain.

  Do not install the refrigerator in locations where the temperature is over 110°F (43°C) 

or below 50°F (10°C ).

6. STABILIZING -

 Make sure the unit is installed in a stable condition with the front 

wheels locked while in use.

7. LEVELING -

 Be sure that the unit levels from the front to the back and side to side.

8. UNIT SHOULD BE ON DEDICATED OUTLET -

 Plug the refrigerator into a wall 

socket exclusively for this appliance. Do not run on extension cord.

9. THE ELECTRICAL PLUG MUST BE ACCESSIBLE WITHOUT MOVING THE UNIT.

10. IF A FOOD STORAGE IS IN POSITION, A MAXIMUM OF ONE SHELF MAY BE 

LOADED LESS THAN 110

lb

 (50

kg

), BUT DO NOT ALLOW LOADS TO  

OVERHANG FROM THE FRONT AND REAR EDGES OF SHELVES.

INSTALLATION

Loss or spoilage of products in your refrigerator/freezer is not covered by warranty.

In addition to following recommended installation procedures, you must run the

refrigerator/ freezer 24 hours prior to usage.

NOTICE TO CUSTOMER

TGM-5R-N#~TGM-72RS_-N#외(영)_미주향.indd   11

2017-06-14   오전 11:01:38

Summary of Contents for TGM-11RV-N Series

Page 1: ...14RV N TGM 22RV N TGM 35R N TGM 48R N TGM 50RS N TGM 69R N TGM 72RS N Please read this manual completely before attempting to install or operate this equipment www turboairinc com May or may not have...

Page 2: ...D APPLIANCE 9 BEFORE YOU CALL FOR SERVICE 9 SPECIFICATIONS 10 SERIAL NUMBER 10 NOTICE TO CUSTOMER 11 INSTALLATION 11 CLEANING 12 BASIC OPERATION 13 CAUTION 14 HOW TO ADJUST A SHELF POSITION AND REPLAC...

Page 3: ...wledge are not included in this manual and are not required Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision This manual uses...

Page 4: ...gerant tubing CAUTION Risk of fire or explosion Dispose of properly in accordance with federal or local regulations Flammable refrigerant used CAUTION Risk of fire or explosion Flammable refrigerant u...

Page 5: ...of refrigerant in your particular appliance is shown on the label inside the cabinet This appliance contains a small amount of propane R 290 or isobutane R 600a refrigerant a natural gas with high env...

Page 6: ...the potential safety hazards under certain conditions we strongly disrecommend any use of an extension cord or an adapter plug Do not under any circumstances cut or remove the ground prong from the po...

Page 7: ...filled with water on top of the appliance If the water spills onto any electrical parts it may lead to fire or electric shock Do not attempt to repair disassemble or alter the appliance It may cause f...

Page 8: ...f fire Do not insert your hand into the bottom area of appliance Any sharp edges may cause personal injury After unplugging the appliance wait at least five minutes before plugging it back in Abnormal...

Page 9: ...n schedules or locations can be obtained from the local disposal authorities PROPER DISPOSAL OF OLD APPLIANCE BEFORE YOU CALL FOR SERVICE IMPORTANT SAFETY INFORMATION For environmental purpose refrige...

Page 10: ...S TGM 5R N 38 M 32 VCT SC M 110 120 V 60Hz R 600a 1 76 oz 50 g 1 2 A TGM 11RV N 38 M 32 VCT SC M 110 120 V 60Hz R 600a 2 12 oz 60 g 2 2 A TGM 14RV N 38 M 32 VCT SC M 110 120 V 60Hz R 600a 2 12 oz 60 g...

Page 11: ...bient temperature will make much lower cooling efficiency 5 INDOOR USAGE ONLY Be sure to install this unit indoor only It should prohibit getting wet from the rain Do not install the refrigerator in l...

Page 12: ...ths 90 days or as needed To clean the condenser unplug the power cord Condenser can be cleaned with vacuum brush or CO2 high pressure air 3 CLEAN THE DRAIN PAN Periodically empty the drain pan which i...

Page 13: ...rature and clock wise or the higher number setting for colder temperature 4 The temp controller is mounted on the evaporator and compressor cycles are determined by detecting the return air temperatur...

Page 14: ...intenance functions or cleaning the refrigerated cabinet Compressor warranties are void if compressor burns out due to low voltage 2 RESTARTING If disconnected wait 5 minutes before restarting 3 POSIT...

Page 15: ...by holding on to the wire Detach the lamp base holder from the lamp base After the work is done up to this stage shelves can be adjusted into a new position Separate the lamp from the lamp socket and...

Page 16: ...s not low enough check for Closure of the doors Installation near a heat source Correct setting of the refrigerator freezer temperature controls Inhibited air circulation Condenser coil is properly cl...

Page 17: ...ting device The unit contains hot food or too much food The unit door is opened too frequently or left open long The temp dial is not on the correct position The condenser is clogged Check the install...

Page 18: ...tallation Additional Three Year Compressor Warranty In addition to the two 2 year warranty stated above Turbo Air warrants its hermetically sealed compressor to be free from defects in both material a...

Page 19: ...INSTALLATION FIRE FLOOD ACTS OF GOD OR IMPROPER ELECTRICAL CONNECTIONS TURBO AIR IS NOT RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF FAILED OR DAMAGED COMPONENTS RESULTING FROM ELECTRICAL POWER FAILUR...

Page 20: ...20 Turbo air TGM 5R N TGM 72RS_ N _ indd 20 2017 06 14 11 01 39...

Page 21: ...21 Turbo air TGM 5R N TGM 72RS_ N _ indd 21 2017 06 14 11 01 39...

Page 22: ...22 Turbo air W TGM 5R N TGM 72RS_ N _ indd 22 2017 06 14 11 01 39...

Page 23: ...tration within 7 days from the date of purchase Failure to comply may result in your warranty being voided Date of Purchase Name of the Dealer City State Zip Code Turbo Air Inc 4184 E Conant St Long B...

Page 24: ...www turboairinc com 4184 E Conant St Long Beach CA 90808 Toll Free 1 800 381 7770 Fax 310 900 1033 Email warranty turboairinc com TGM 5R N TGM 72RS_ N _ indd 24 2017 06 14 11 01 39...

Reviews: